Skip to main content
  • Original research
  • Open access
  • Published:

Does point-of-care ultrasonography cause discomfort in patients admitted with respiratory symptoms?

Abstract

Background

This study aimed to assess the patient-rated level of discomfort during point-of-care ultrasonography (POCUS) of the heart, lungs and deep veins in a population of patients admitted to an ED with respiratory symptoms and to what extent the patients would accept being assessed by the use of POCUS if they had to be examined for possible disease.

Methods

A questionnaire-based observational study was conducted in an ED. Inclusion criteria were one or more of the following: respiratory rate > 20/min, oxygen saturation < 95 %, oxygen therapy initiated, dyspnoea, cough or chest pain. Patients were examined by the use of POCUS of the heart, lungs and deep veins. Patient-rated level of discomfort and acceptance were assessed using a standardised questionnaire.

Results

The median duration of the sonographic examinations was 12 min (IQR 11–13, range 9–23). The median patient-rated level of discomfort for all three types of POCUS was 1 (IQR 1–1, range 1–8) on a scale from 1 to 10. All but one patient (99.6 % (95 % CI: 98.9-100 %)), would accept being examined by the use of POCUS as a part of routine ED diagnostics.

Conclusions

The patient-rated level of discomfort during POCUS of the heart, lungs and deep veins is very low and the vast majority of patients would accept being assessed by the use of POCUS if the patients once again had to be examined for possible disease.

Background

Diagnostic ultrasonography is a non-invasive and radiation free procedure which also has the advantage of causing minimal patient discomfort and pain [1]. The part of this statement describing patient discomfort and pain seems so obvious that it, by many, would be considered as being an axiom. This is reflected by the fact that the research assessing the benefits and drawbacks of ultrasonography seen from the patient’s perspective is limited. Both patient satisfaction and discomfort during various guided invasive procedures, transvaginal ultrasound, or stress tests involving the use of ultrasound has been assessed [28]. However, little is known of the level of patient discomfort during an examination involving diagnostic ultrasound without invasive or stress related procedures. A diagnostic accuracy study of lung ultrasound for the diagnosis of rib fractures reported problems with inflicting pain in some of the patients participating in the study, the degree of pain were however not systematically measured or assessed in the study [9].

Point-of-care ultrasonography (POCUS) is widely used in emergency departments (ED) and its use is expected to rise further in the future [1012]. The use of POCUS in an ED has been shown to have a positive impact on patient satisfaction and health care consumption [1316]. Patients admitted to an ED with respiratory symptoms are already in distress due to the symptoms in themselves, whether POCUS in itself causes or aggravates the patient experienced distress in such a patient population has not been explored [17]. Research is needed in order to assess whether POCUS can cause distress and whether patients are willing to accept POCUS as a standard diagnostic procedure in the ED.

A questionnaire-based observational study was conducted in a population of patients admitted to an ED with respiratory symptoms to assess the patient-rated level of discomfort during POCUS of the heart, lungs and deep veins and to what extent the patients would accept being assessed by the use of POCUS if they had to be examined for possible disease.

Methods

Design

The study was conducted as a questionnaire-based observational study with data collection alongside two studies assessing the diagnostic accuracy and impact of POCUS in admitted patients with respiratory symptoms [12, 18].

Setting, study population and ethics

The study took place at the medical section of the ED at Odense University Hospital, Denmark. Corresponding to the inclusion periods of the simultaneously conducted diagnostic accuracy studies two observational periods between November 2010 and May 2011 and December 2011 to March 2013 were used [12, 18]. The ED has approximately 58,800 visits and 12,000 acute admissions each year, whereas nearly 7700 (64 %) of the admissions are related the medical section of the ED. In Denmark, all acute hospital admissions are in public hospitals and occur either as a direct emergency admission or by referral from a general practitioner. Adult patients admitted with respiratory complaints are all admitted to the medical ED, exceptions being trauma patients and patients triaged directly to the department of cardiology on a suspicion of heart disease. Hemodynamic stable patients suspected of having deep vein thrombosis (DVT) or pulmonary embolism (PE), are seen in the department’s out-patient clinic and not admitted to the ED.

The study was conducted according to the Helsinki Declaration and approved by the Committee on Biomedical Research Ethics for The Region of Southern Denmark (ID S-2010074) and the Danish Data Protection Agency (ID 2010-41-5142). Some of the enrolled patients were part in a randomized clinical trial involving the use of POCUS (registered at http://clinicaltrials.gov (NCT01486394)).

Participants

All patients admitted to the medical ED were following triage screened for study participation by a study investigator. Patients were included if they fulfilled one or more of the following findings:

  • Respiratory rate > 20 breaths per minute

  • Oxygen saturation < 95 %

  • Oxygen therapy initiated

Or if the patients answered yes to ≥ 1 of the following questions when screened:

  • Do you feel or have you felt any dyspnoea prior to the admission?

  • Do you experience or have you experienced coughing prior to the admission?

  • Do you experience or have you experienced chest pain prior to the admission?

Exclusion criteria

  • Permanent mental disability

  • Patient age < 18 years

  • The sonographic examinations could not be performed within one hour after the primary assessment

POCUS

As a part of the diagnostic accuracy studies POCUS of the heart, lungs and deep veins was performed within one hour after the primary clinical assessment. All three types of sonography were performed in all of the included patients. The sonographic examinations were performed according to the following protocols:

Focus Assessed Transthoracic Echocardiography (FATE): Performed with a M4S or M5S phased array transducer (1.5 – 4.0 / 1.5-4.6 MHz) (General Electric Company) using the FATE protocol [19].

Focused lung ultrasound (FLUS): Performed with an 8C or 3CRF micro convex transducer (3.5 – 11.5 / 2.0-4.2 MHz) or a C1-5 curved abdominal transducer (2.0-5.0 MHz) (General Electric Company), using a modification of the principles described by Lichtenstein and Volpicelli (Fig. 1) [20, 21].

Fig. 1
figure 1

Examples of used transducer positions. a Transducer placed for subcostal view during FATE. b Transducer placed in an intercostal space at the anterior surface of the chest during FLUS. c Transducer placed at the popliteal crease for assessment of the popliteal vein during LCU

Limited compression ultrasonography (LCU): Performed with a 12 L or ML6-15 linear transducer (5.0 – 13.3 / 4.5-15 MHz) (General Electric Company) according to the American College of Emergency Medicine’s imaging criteria compendium [22].

The patients themselves choose the preferred position to assume while being examined with sonography (e.g. sitting, supine). Examples of transducer positions for the three different sonography protocols are shown in Fig. 1.

All the sonographic examinations were made by the same physician qualified in POCUS (CBL) (FATE examinations > 200, F-LUS examinations > 400, LCU examinations > 200). A Logiq S8 or Vivid S6 (General Electric Company) ultrasound system was used for all examinations.

The time used for the ultrasonographic examinations was defined as the time used from when the transducer touched the patient’s skin for the first time to the examination had been completed and stored on the ultrasound system. The feasibility of the ultrasonographic examinations were assessed according to predefined criteria (see Additional file 1).

Assessment of patient-rated level of discomfort

To measure the patient-rated level of discomfort during POCUS a simple questionnaire including 4 items was used. Three of the items were Likert items in which the patient were asked to assess the level of discomfort experienced during FATE, FLUS and LCU on a scale from one to ten. The score one corresponded to no discomfort and the score ten corresponded to the worst level of discomfort imaginable by the patient. A score of one to two was believed as being a low score; hence pragmatically it was chosen that if the patient scored any item more than two, the patient was asked whether they could explain the reason for the increased score.

Patient-rated discomfort was chosen in order to encompass a variety of different aspects causing patient discomfort during the examination (e.g. patient position during the examination, pressure being applied on the skin by the transducer, cooperation to the examination while having to cope with respiratory distress).

The final questionnaire item concerned whether the patient would accept or decline being examined by the use of POCUS if the patient once again had to be examined for possible disease. The questionnaire was filled out either by self-completion or by assistance from a study investigator to solely read up the questions. All questionnaires were filled out immediately after the sonographic examination. The questionnaire was solely developed for this study and was not based on any previously validated questionnaires. The questionnaire can be found in its original form (Danish) and an English version in the Additional file 1.

Statistical analysis

From the two observation periods data was joined as one cross-section and descriptive statistics were performed including: demographic characteristics, medical history, patient symptoms and vital signs measured at arrival. Time spent for the sonographic examinations were calculated as a median with corresponding 25th and 75th interquartiles (IQR) and range. Feasibility of the sonographic examination was calculated as a proportion with corresponding 95 % confidence interval (CI). Patient-rated levels of discomfort during the three sonographic examinations were calculated as median with corresponding 25th and 75th IQR and range. The number of patients rating the level of discomfort two or lower and the number of patients who would accept being assessed by the use of POCUS if they had to be examined for possible disease were calculated as proportions with corresponding 95 % CIs. Data analysis was conducted using Stata Release Version 11.0 (StataCorp, College Station, TX, USA).

Results

Baseline patient characteristics

A total of 1130 patients were assessed for eligibility. Inclusion criteria were not met in 698 (61.8 %) of the patients and 133 (11.8 %) patients had to be excluded, either due to the patient declining to participate in the study or due to one or more of the exclusion criteria being present. The most common cause for study exclusion was permanent mental disability. A total of 299 (26.5 %) patients remained for study inclusion. Following sonography, 26 patients were not able to fill out the questionnaire with or without assistance and 2 patients withdrew informed consent for study participation during the hospital stay. This left 271 patients remaining in the study. The study flow diagram is presented in Fig. 2 and base-line characteristics of included patients are summarized in Table 1. The results of the screening process for the different patient groups can be found in Table S1 in the Additional file 1.

Fig. 2
figure 2

Study flow diagram

Table 1 Base-line characteristics of the patients

POCUS

The median duration of the sonographic examinations was 12 min (IQR 11–13, range 9–23). The patient was in sitting position in 186 (62.6 % (95 % CI: 57.1-68.1 %)) and supine position in 111 (37.4 % (95 % CI: 31.8-42.9 %)), respectively. Feasibility for the sonographic examinations were: FATE 99.7 % (95 % CI: 98.1-100 %), FLUS 100 % (95 % CI: 98.8-100 %) and LCU 98.7 % (95 % CI: 96.6-99.6 %).

Questionnaire items

The median patient-rated level of discomfort for all three types of POCUS was 1 (IQR 1–1, range 1–8). The proportion of patients rating the level of discomfort two or lower was: FATE 96.7 % (95 % CI: 94.5-98.8 %), FLUS 98.2 % (95 % CI: 96.5-99.8 %) and LCU 98.2 % (95 % CI: 96.5-99.8 %). The proportion of patients rating the level of discomfort two or lower for both the heart, lung and deep vein examinations was 95.2 % (95 % CI: 92.6-97.8 %). For patients who rated the level of discomfort higher than two during one or more of the POCUS examinations, the causes are summarized in Table 2. All but one patient (99.6 % (95 % CI: 98.9-100 %)) would accept being examined by the use of POCUS if the patient once again had to be examined for possible disease.

Table 2 Patient rated level of discomfort during assessment with POCUS

Discussion

In patients with respiratory symptoms admitted to an ED POCUS of the heart, lungs and deep veins seems to cause little discomfort. The vast majority of these patients would accept being assessed by POCUS if it was a part of the routine ED assessment. The study results provide experimental support for the axiom that claims that ultrasonography is not associated with patient pain or discomfort.

The study population is believed to comprise a representative sample of patients with respiratory symptoms being admitted to an ED in Denmark. Despite the different inclusion criteria and study methods, the base-line characteristics of the patients (Table 1) are comparable with other studies in which ED patients with respiratory symptoms have been assessed [2328]. As seen in Fig. 2, a relatively large proportion of the patients met inclusion criteria but still had to be excluded. This could have caused selection bias if the excluded patients were sicker than the included patients and thereby possibly more likely to experience discomfort during the examination. Based on the triage colour obtained as a part of the screening process (see Additional file 1, Table 1), the patients in whom POCUS was not performed generally received a lower triage colour than those in which POCUS was performed. The patients who were excluded after POCUS had been performed however generally had a higher triage colour than those patients remaining for study analysis. The potential selection bias introduced by excluding patients after the POCUS could however not be avoided since data could only be collected if the patients were able to fill out the questionnaire with or without assistance.

Other studies have documented the positive impact on patient satisfaction and health care consumption when POCUS is used in an ED [1316]. That patients generally have a positive attitude towards POCUS is further supported by the study results showing that nearly all included patients would accept being examined using POCUS if it was a standard diagnostic procedure. This seems also to apply for patients experiencing an increased level of discomfort during the examination.

Thirteen patients rated the level of discomfort during one or more of the POCUS examinations higher than two (Table 3). An increased level of discomfort was most often due to an underlying disease or the result of an intervention (e.g. surgery, resuscitation) causing localised pain. Three of the patients with a slight increase in the level of discomfort did not have a specific cause. One patient rated the level of discomfort very high for all three types of POCUS (Table 3, patient no. 143). The patient described a very unpleasant, buzzing sensation going through the entire body, as soon as the transducer touched the patient’s skin. This 44-year old male patient suffered from a known psychiatric disorder, and was admitted to the ED with dyspnoea, chest pain and a cough following inhalation of toxic fumes. No obvious explanation for the patients experienced sensation during POCUS could be given. The same patient would decline being examined by the use of POCUS if the patient once again had to be examined for possible disease.

Table 3 Patients rating level of discomfort during assessment with POCUS higher than two in any of the three types of sonography

The results support the finding of another study, which indicated that underlying disease may cause increased patient discomfort or pain during an ultrasound examination [9]. The number of patients declining to participate in the study comprised 4.2 % of all patients assessed for eligibility and would have comprised 13.6 % of the study population if they all had accepted to participate in study (Fig. 2).

Limitations

The study was conducted as a single centre study; hence the results can not necessarily be generalized to other EDs or other settings. Additionally, all sonographic examinations were performed by the same physician also affecting the external validity. The advantage of this was, however, a consistent ultrasound examination procedure giving rise to almost elimination of inter-observer-variability. The observed feasibility was very high, which is an indicative of both sufficient pressure being applied and sufficient time being spent performing the examinations. Hence it seems that sonographic examination quality was not compromised in order to decrease possible patient discomfort.

To our knowledge there is no validated questionnaire for the assessment of patient discomfort during sonographic examination; a simple questionnaire developed for the study was used instead. The questionnaire fulfilled face validity. However, a more extensive validation, e.g. content validity was not performed. No data on patient discomfort were available prior to the study, on which an optimal discomfort scale of the questionnaire could be based. It was decided that the primary interest was to identify patients with significant discomfort during the procedure rather than being able to discriminate between patients with a slightly increased level of discomfort. Hence, we developed a non-validated 10-point Likert scale from 1–10 in which 10 corresponded to the worst level of discomfort imaginable by the patient. The scale should thus be able to identify patients with a significantly increased discomfort during the procedure, but would be less useful for discriminating between patients with only a slightly increased level of discomfort.

A potential disadvantage is healthy volunteer bias, i.e. the possibility of selecting patients with certain characteristics among those accepting be examined by ultrasonography. Never the less, as only a minimum of the patients declined the examination being supplemented with POCUS; we have no reason to believe that this type of selection bias may have been a major drawback.

As the questionnaire was performed in the frame of an emergency admission, this could have let to a framing effect resulting in a more positive attitude towards sonographic examination. The frame however reflects the setting and patients in which POCUS is used in clinical practice. If the patients had been asked to fill out the questionnaire later on, the time given for patient reflection, the presence of framing, these potential effect modifiers could affected the study results negatively due to primarily recall bias.

Clinical implications

Patients admitted with respiratory symptoms may experience stress and anxiety due to both symptoms caused by the underlying disease and simply by being admitted to hospital. Despite of this, POCUS is generally well accepted and in itself causes little discomfort in these patients. Patients with comorbidity causing localised pain (e.g. intercostal muscle myalgia, rib fractures, neuropathy) may experience an increased level of discomfort. When performing POCUS in patients with such conditions, the patient should prior to the examination be informed of an increased risk of experiencing discomfort. Still, POCUS should not be withheld in these patients since the patient-rated level of discomfort is low and the patients despite of the increases discomfort nonetheless accepts being examined by the use of POCUS.

Conclusion

In patients admitted to an ED with respiratory symptoms, the patient-rated level of discomfort during POCUS of the heart, lungs and deep veins is very low. The vast majority of patients would accept being examined by the use of POCUS if the patients once again had to be examined for possible disease.

References

  1. Grainger RG, Allison D, Adam A, Dixon AK. Grainger's and Allison's Diagnostic Radiology: A Textbook of Medical Imaging. Churchill Livingstone: Elsevier; 2008.

    Google Scholar 

  2. Steinfort DP, Irving LB. Patient satisfaction during endobronchial ultrasound-guided transbronchial needle aspiration performed under conscious sedation. Respir Care. 2010;55:702–6.

    PubMed  Google Scholar 

  3. Hsu YC, Wu YC, Kao HL, Pan RY, Lee MS, Huang GS. Factors influencing discomfort during anterior ultrasound-guided injection for hip arthrography. J Chin Med Assoc. 2013;76:510–6.

    Article  PubMed  Google Scholar 

  4. Yap LP, McNally E. Patient's assessment of discomfort during ultrasound-guided injection of Morton's neuroma: selecting the optimal approach. J Clin Ultrasound. 2012;40:330–4.

    Article  PubMed  Google Scholar 

  5. Dutta RL, Economides DL. Patient acceptance of transvaginal sonography in the early pregnancy unit setting. Ultrasound Obstet Gynecol. 2003;22:503–7.

    Article  CAS  PubMed  Google Scholar 

  6. Rosati P, Guariglia L. Acceptability of early transvaginal or abdominal sonography in the first half of pregnancy. Arch Gynecol Obstet. 2000;264:80–3.

    Article  CAS  PubMed  Google Scholar 

  7. Aydin A, Yilmazer MS, Gurol T, Celik O, Dagdeviren B. Ondansetron administration before transoesophageal echocardiography reduces the need for sedation and improves patient comfort during the procedure. Eur J Echocardiogr. 2010;11:752–5.

    Article  PubMed  Google Scholar 

  8. Wagner S, Mohr-Kahaly S, Nixdorff U, Kolsch B, Menzel T, Wittlich N, et al. [Prospective study of subjective stress caused by dobutamine stress echocardiography–effect on diagnostic accuracy]. Z Kardiol. 1996;85:588–95.

    CAS  PubMed  Google Scholar 

  9. Hurley ME, Keye GD, Hamilton S. Is ultrasound really helpful in the detection of rib fractures? Injury. 2004;35:562–6.

    Article  PubMed  Google Scholar 

  10. Moore CL, Copel JA. Point-of-care ultrasonography. N Engl J Med. 2011;364:749–57.

    Article  CAS  PubMed  Google Scholar 

  11. Emergency ultrasound guidelines. Ann Emerg Med. 2009, 53:55070.

  12. Laursen CB, Sloth E, Lassen AT, Christensen R, Lambrechtsen J, Madsen PH, et al. Point-of-care ultrasonography in patients admitted with respiratory symptoms: a single-blind, randomised controlled trial. The Lancet Respiratory medicine. 2014;2:638–46.

    Article  PubMed  Google Scholar 

  13. Lindelius A, Torngren S, Nilsson L, Pettersson H, Adami J. Randomized clinical trial of bedside ultrasound among patients with abdominal pain in the emergency department: impact on patient satisfaction and health care consumption. Scand J Trauma Resusc Emerg Med. 2009;17:60.

    Article  PubMed Central  PubMed  Google Scholar 

  14. Howard ZD, Noble VE, Marill KA, Sajed D, Rodrigues M, Bertuzzi B, Liteplo AS. Bedside Ultrasound Maximizes Patient Satisfaction. J Emerg Med. 2013.

  15. Durston W, Carl ML, Guerra W. Patient satisfaction and diagnostic accuracy with ultrasound by emergency physicians. Am J Emerg Med. 1999;17:642–6.

    Article  CAS  PubMed  Google Scholar 

  16. Krubel R, Freedman D, Bursch B. Effects of transvaginal sonography on pregnant patients' perceptions of care in the ED. Am J Emerg Med. 1996;14:232–3.

    Article  CAS  PubMed  Google Scholar 

  17. Parshall MB, Welsh JD, Brockopp DY, Heiser RM, Schooler MP, Cassidy KB. Dyspnea duration, distress, and intensity in emergency department visits for heart failure. Heart Lung. 2001;30:47–56.

    Article  CAS  PubMed  Google Scholar 

  18. Laursen CB, Sloth E, Lambrechtsen J, Lassen AT, Madsen PH, Henriksen DP, et al. Focused sonography of the heart, lungs, and deep veins identifies missed life-threatening conditions in admitted patients with acute respiratory symptoms. Chest. 2013;144:1868–75.

    Article  PubMed  Google Scholar 

  19. Jensen MB, Sloth E, Larsen KM, Schmidt MB. Transthoracic echocardiography for cardiopulmonary monitoring in intensive care. Eur J Anaesthesiol. 2004;21:700–7.

    Article  CAS  PubMed  Google Scholar 

  20. Lichtenstein D. General Ultrasound in the Critically Ill. Springer; 2007

  21. Volpicelli G, Mussa A, Garofalo G, Cardinale L, Casoli G, Perotto F, et al. Bedside lung ultrasound in the assessment of alveolar-interstitial syndrome. Am J Emerg Med. 2006;24:689–96.

    Article  PubMed  Google Scholar 

  22. Emergency ultrasound imaging criteria compendium. American College of Emergency Physicians. Ann Emerg Med. 2006, 48:487510.

  23. Ray P, Birolleau S, Lefort Y, Becquemin MH, Beigelman C, Isnard R, et al. Acute respiratory failure in the elderly: etiology, emergency diagnosis and prognosis. Crit Care. 2006;10:R82.

    Article  PubMed Central  PubMed  Google Scholar 

  24. Leuppi JD, Dieterle T, Koch G, Martina B, Tamm M, Perruchoud AP, et al. Diagnostic value of lung auscultation in an emergency room setting. Swiss Med Wkly. 2005;135:520–4.

    PubMed  Google Scholar 

  25. Kimura BJ, Bocchicchio M, Willis CL, Demaria AN. Screening cardiac ultrasonographic examination in patients with suspected cardiac disease in the emergency department. Am Heart J. 2001;142:324–30.

    Article  CAS  PubMed  Google Scholar 

  26. Liteplo AS, Marill KA, Villen T, Miller RM, Murray AF, Croft PE, et al. Emergency thoracic ultrasound in the differentiation of the etiology of shortness of breath (ETUDES): sonographic B-lines and N-terminal pro-brain-type natriuretic peptide in diagnosing congestive heart failure. Acad Emerg Med. 2009;16:201–10.

    Article  PubMed  Google Scholar 

  27. Prosen G, Klemen P, Strnad M, Grmec S. Combination of lung ultrasound (a comet-tail sign) and N-terminal pro-brain natriuretic peptide in differentiating acute heart failure from chronic obstructive pulmonary disease and asthma as cause of acute dyspnea in prehospital emergency setting. Crit Care. 2011;15:R114.

    Article  PubMed Central  PubMed  Google Scholar 

  28. Zanobetti M, Poggioni C, Pini R. Can chest ultrasonography replace standard chest radiography for evaluation of acute dyspnea in the ED? Chest. 2011;139:1140–7.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Christian B. Laursen.

Additional information

Competing interests

Christian B. Laursen: Has received payment as author of e-learn material and as course director / instructor for courses in ultrasound organized by USabcd A/S.

Erik Sloth: Has received lecturing fees from BK, GE and Philips.

Annmarie Touborg Lassen: None.

Jesper Rømhild Davidsen: Without relation to the submitted work he has received sponsored participation at ERS Congress in 2009 and a fee for organizing education in 2010 by AstraZeneca, a Novartis sponsored symposium in 2011 and 2012, and by Boehringer Ingelheim sponsored participation at ERS Congress in 2013.

Jess Lambrechtsen: None.

Daniel Pilsgaard Henriksen: None.

Poul Henning Madsen: Has recieved a personal fee as a steering committee member, Nordic Forum for Future Respiratory Specialists meeting 2010 (AstraZeneca). Has received a personal fee for giving a lecture at an event arranged by Intermune (2014). Has had travel and accommodation expenses covered by: BoehringerIngelheim/Pfizer (2010), AstraZeneca (2010), Olympus (2010), Chiesi Pharmaceutici (2011), BoehringerIngelheim/Pfizer (2011), Nycomed (2011), Almirall (2011), Novartis (2012) and Norpharma (2013).

Finn Rasmussen: None.

Authors' contributions

CBL has contributed substantially to conception and design of the study, acquisition and analysis of data and drafted the submitted article and approved the final version. ES, AML, JRD, JL, DPH, PHM and FR have contributed substantially to conception and design of the study, analysis and interpretation of data and revised the article critically for important intellectual content and approved the final version.

Additional file

Additional file 1:

Feasibility of the sonographic examinations.

Rights and permissions

This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly credited. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Laursen, C.B., Sloth, E., Lassen, A.T. et al. Does point-of-care ultrasonography cause discomfort in patients admitted with respiratory symptoms?. Scand J Trauma Resusc Emerg Med 23, 46 (2015). https://doi.org/10.1186/s13049-015-0127-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • DOI: https://doi.org/10.1186/s13049-015-0127-x

Keywords